MRC | Criteria | Characteristic |
---|
FEAT | Special Features | SECOND TUBING SEGMENT IS BERYLLIUM COPPER. SECOND FLANGE IS ATTACHED TO 4.5 INCH X 5.25 INCH SLOTTED MOUNTING PLATE |
AHTN | Flange Connecting Hole Diameter | 0.168 INCHES NOMINAL FIRST FLANGE FIRST CONNECTION FACILITY |
MATT | Material | BERYLLIUM SECOND TUBING SEGMENT |
AHTW | Voltage Standing Wave Ratio | 1.15 |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLEX | Flexibility | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | Flexibility | RIGID FIRST TUBING SEGMENT |
FLEX | Flexibility | RIGID THIRD TUBING SEGMENT |
AAJF | Thread Direction | RIGHT-HAND SECOND FLANGE SECOND CONNECTION FACILITY |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
CZKN | Specified Frequency | 9.4 GIGAHERTZ MAXIMUM |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY |
SFTT | Surface Treatment | SILVER SECOND TUBING SEGMENT INSIDE SURFACES |
CQGM | Maximum Operating Pressure | 10.0 POUNDS PER SQUARE INCH GAGE |
CQHN | Waveguide Outside Width | 1.010 INCHES NOMINAL |
AAJD | Thread Class | 3A SECOND FLANGE SECOND CONNECTION FACILITY |
CRFH | Waveguide Inside Width | 0.998 INCHES NOMINAL |
THSD | Thread Series Designator | UNJF SECOND FLANGE SECOND CONNECTION FACILITY |
CQJX | Nominal Thread Size | 0.162 INCHES SECOND FLANGE SECOND CONNECTION FACILITY |
MRC | Decoded Requirement | Clear Text Reply |
CTCJ | Flange Style | COVER TYPE SECOND FLANGE |
SFTT | Surface Treatment | PLASTIC VINYL SECOND TUBING SEGMENT OUTSIDE SURFACES |
CRLB | Waveguide Inside Height | 0.395 INCHES NOMINAL |
MATT | Material | ALUMINUM THIRD TUBING SEGMENT AND FLANGE |
AHRV | Tubing Wall Construction Style | INTERLOCKED SECOND TUBING SEGMENT |
AHRW | Tubing Twist Type | STRAIGHT TWIST SECOND TUBING SEGMENT |
AHSF | Flange Quantity | 2 |
CSFC | Waveguide Outside Height | 0.507 INCHES NOMINAL |
AHRV | Tubing Wall Construction Style | SEAMLESS FIRST TUBING SEGMENT |
AHRV | Tubing Wall Construction Style | SEAMLESS THIRD TUBING SEGMENT |
AHSZ | Flange Outside Width | 1.625 INCHES NOMINAL SECOND FLANGE |
AGAV | End Item Identification | COAST GUARD HH60J AIRCRAFT WEATHER RADAR |
AHTD | Flange Depth | 0.320 INCHES NOMINAL SECOND FLANGE |
SFTT | Surface Treatment | PAINT FIRST TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
AHRX | Tubing Twist Angle In Deg | 90.0 SECOND TUBING SEGMENT |
MATT | Material | ALUMINUM FIRST TUBING SEGMENT AND FLANGE |
SFTT | Surface Treatment | PAINT THIRD TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
AHTA | Flange Outside Height | 1.635 INCHES NOMINAL SECOND FLANGE |
AHSX | Flange Inside Width | 0.427 INCHES NOMINAL SECOND FLANGE |
AHSY | Flange Inside Height | 0.395 INCHES NOMINAL SECOND FLANGE |
AHTX | Insertion Loss In Decibels | 0.3 |