Aerospace Performance Parts is pleased to offer immediate purchasing options for Ami Coast Magnetics Inc part number 80174, which you have taken interest in. This Coil Electrical item is listed alongside the NSN 5950-01-370-2775 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number 80174 or any other FSC 5950 Coils and Transformers components we carry from Ami Coast Magnetics Inc under CAGE Code 05254, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 5950-01-370-2775 part number 80174 today, knowing we will support all your operational needs with care.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-370-2775 Item PartTypeName: COIL,ELECTRICAL | 5950 | 013702775 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
90C2 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | MOUNTING HOLE DIAMETER | 0.192 INCHES NOMINAL SINGLE GROUP |
ADAR | BODY OUTSIDE DIAMETER | 0.600 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 1.100 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD AND TINNED WIRE LEADS AND SPECIAL MARKING |
CRBZ | WINDING OPERATING CURRENT | 90.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 7.50 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
CRGS | DC RESISTANCE RATING IN OHMS | 75.000 SINGLE COMPONENT SINGLE WINDING |
FEAT | SPECIAL FEATURES | NORTH POLE POLARITY INDICATOR DOT |