Aerospace Performance Parts is pleased to offer immediate purchasing options for Drs Sustainment Systems Inc part number 654342-2, which you have taken interest in. This Power Supply item is listed alongside the NSN 6130-01-283-9011 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number 654342-2 or any other FSC 6130 Converters Electrical Non Rotating components we carry from Drs Sustainment Systems Inc under CAGE Code 20418, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 6130-01-283-9011 part number 654342-2 today, knowing we will support all your operational needs with care.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-283-9011 Item PartTypeName: POWER SUPPLY | 6130 | 012839011 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
654342-2 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.620 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | FTF 15 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 126.5 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 207.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 253.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 11.4 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 12.6 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 128.2 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 141.7 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.7 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 52.2 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 57.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -25.0/71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 150.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |