Aerospace Performance Parts is pleased to offer immediate purchasing options for Ge Kaye Instruments Inc part number HTR-400, which you have taken interest in. This Control Humidity item is listed alongside the NSN 6685-01-483-1283 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number HTR-400 or any other FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments components we carry from Ge Kaye Instruments Inc under CAGE Code 17466, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 6685-01-483-1283 part number HTR-400 today, knowing we will support all your operational needs with care.
MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | ITEM AKA: DRY WELL TEMPERATURE REFERENCE; WGT: 18 LBS; DIM: 12.5"" DEPTH; OPERATING TEMPERATURE: 5 - 50 DEG C;SET POINT ACCURACY: +/- 0.2 DEG C TO 300 DEG C, +/- 0.3 DEG C AT 400 DEG C; SETPOINT STABILITY +/- 0.02 DEG C/DAY TO 300 DEG C, +/- 0.05 DEG C/DAY TO 400 DEG C; DISPLAY RESOLUTION +/- 0.01 DEG C OR F; DISPLAY TYPE: LED, CENTIGRADE OR FAHR.; TYPICAL WARM-UP TIME: 5 MIN AMBIENT TO 90 DEG C, 3 MIN: 90 TO 125 DEG C, 25 MIN: AMBIENT TO 350 DEG C; TYPICAL COOL DOWN TIMES: 20 MIN: 125 TO 90 DEG C, 15 MIN: 350 TO 270 DEG C; FAULT PROTECTION: SENSOR BURNOUT PROTECTION, OVER TEMPERATURE THERMAL CUTOUT, ELECTRICAL FUSE: 115V, 6A; 230V, 3A; WELL DIMENSIONS: 2 REFERENCE WELLS AT 6.7MM (0.265"") DIA. X 127MM (0.265"") DIA. X 127MM (5"") DEEP 8 CALIBRATION WELLS AT 9MM (0.354"") DIA. X 155MM (6.1"") DEEP; CALIBRATION WELL CAPACITY: 24 OR 32 DEPENDING ON WIRE SIZE |
CHQR | MAXIMUM OVERALL HEIGHT | 13.500 INCHES |
AXGY | MOUNTING METHOD | PLATFORM |
CHQQ | MAXIMUM OVERALL WIDTH | 7.800 INCHES |
CKRD | SENSING ELEMENT TYPE AND LOCATION | THERMOCOUPLE INTERNAL |
AFGA | OPERATING TEMP RANGE | 25.0 TO 400.0 DEG CELSIUS |