Aerospace Performance Parts is pleased to offer immediate purchasing options for Litton Systems Inc part number 841321-1, which you have taken interest in. This Transformerpower item is listed alongside the NSN 5950-01-334-9753 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number 841321-1 or any other FSC 5950 Coils and Transformers components we carry from Litton Systems Inc under CAGE Code 13973, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 5950-01-334-9753 part number 841321-1 today, knowing we will support all your operational needs with care.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-334-9753 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013349753 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5T392 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 2.150 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.700 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 29.70 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 7 TURRET |
ABHP | OVERALL LENGTH | 4.000 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT WATER RESISTANT AND VIBRATION RESISTANT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |