Aerospace Performance Parts is pleased to offer immediate purchasing options for Military Specifications part number MILR15109, which you have taken interest in. This Resistor Fixed Wire Wound item is listed alongside the NSN 5905-00-468-3734 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number MILR15109 or any other FSC 5905 Resistors components we carry from Military Specifications under CAGE Code 81349, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 5905-00-468-3734 part number MILR15109 today, knowing we will support all your operational needs with care.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-468-3734 Item PartTypeName: RESISTOR,FIXED,WIRE WOUND | 5905 | 004683734 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P4745885G4 | C | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQFD | SECTION NOMINAL RESISTANCE | 2.310 OHMS 9TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.500 OHMS 10TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.500 OHMS 11TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.500 OHMS 12TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.920 OHMS 13TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.920 OHMS 14TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.130 OHMS 15TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.130 OHMS 16TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.740 OHMS 17TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.740 OHMS 18TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.910 OHMS 19TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 3.910 OHMS 20TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 4.560 OHMS 21ST SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 4.560 OHMS 22ND SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 5.200 OHMS 23RD SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 5.200 OHMS 24TH SECTIONUNABLE TO DECODE |
CQFK | FIXED TAP TERMINAL TYPE | TAB,SOLDER LUGTAB,SOLDER LUGTAB,SOLDER LUG |
CSCF | TERMINAL TYPE | TAB,SOLDER LUGTAB,SOLDER LUGTAB,SOLDER LUG |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH END |
AAPP | ELECTRICAL RESISTANCE | 72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS72.300 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.000 TO 10.000 |
AAPR | FIXED TAP QUANTITY | 232323232323232323 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 425.0 |
AARE | REACTANCE CHARACTERISTIC | INDUCTIVEINDUCTIVEINDUCTIVEINDUCTIVEINDUCTIVE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.062 INCHES NOMINAL1.062 INCHES NOMINAL1.062 INCHES NOMINAL1.062 INCHES NOMINAL1.062 INCHES NOMINAL |
ABPM | BODY DIAMETER | 2.000 INCHES NOMINAL2.000 INCHES NOMINAL2.000 INCHES NOMINAL2.000 INCHES NOMINAL2.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 15.000 INCHES NOMINAL15.000 INCHES NOMINAL15.000 INCHES NOMINAL15.000 INCHES NOMINAL15.000 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 545.000 FREE AIR545.000 FREE AIR545.000 FREE AIR545.000 FREE AIR545.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | UNINCLOSEDUNINCLOSEDUNINCLOSEDUNINCLOSEDUNINCLOSED |
CQFD | SECTION NOMINAL RESISTANCE | 1.830 OHMS 1ST SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.830 OHMS 2ND SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.830 OHMS 3RD SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.830 OHMS 4TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.980 OHMS 5TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.980 OHMS 6TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 1.980 OHMS 7TH SECTIONUNABLE TO DECODE |
CQFD | SECTION NOMINAL RESISTANCE | 2.310 OHMS 8TH SECTIONUNABLE TO DECODE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.