Aerospace Performance Parts is pleased to offer immediate purchasing options for Parker Hannifin Corporation part number 33-0315, which you have taken interest in. This Filter Element Flui item is listed alongside the NSN 4330-01-503-3219 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number 33-0315 or any other FSC 4330 Centrifugals Separators And Pressure And Vacuum Filters components we carry from Parker Hannifin Corporation under CAGE Code 62144, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 4330-01-503-3219 part number 33-0315 today, knowing we will support all your operational needs with care.
MRC | Criteria | Characteristic |
---|---|---|
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | FILTER ELEMENT, FLUID |
ADNH | FILTRATION RATING IN MICRONS | 10.0 ABSOLUTE AND 5.0 NOMINAL |
AGAV | III END ITEM IDENTIFICATION | REVERSE OSMOSIS DESALINATOR |
APGF | DESIGN TYPE | NONREUSABLE |
AZTL | BODY OVERALL LENGTH | 9.750 INCHES NOMINAL |
CRXW | FILTERING MEDIA DESIGN | GRANULE SINGLE FILTERING MEDIA RESPONSE |
AZKQ | TEMP RATING | 125.0 DEG FAHRENHEIT MAXIMUM |
ADNK | FLOW DIRECTION | OUTSIDE IN |
FEAT | SPECIAL FEATURES | MAXIMUM OPERATING PRESSURE: 250 PSIG; COLLAPSE PRESSURE: 200 PSID; FILTER WILL NOT CHANNEL OR BYPASS, DUE TO THE EXTREME UNIFORMITY OF EXTRUDED CARBON CORE, CAN BE INSTALLED WITHOUT PREFILTRATION; FILTERS ARE FINISHED WITH AN OUTER POLYPROPYLENE SPUNBONDED PREFILTRATION MEDIUM; PROTECTIVE POLYPROPYLENE NETTING IS APPLIED TO THE EXTERIOR OF THE CARTRIDGE; POLYPROPYLENE END CAPS WITH COMPRESSION GASKETS; FILTERS ARE NOT BE AUTOCLAVED OR STEAMSTERILIZED |
MATT | MATERIAL | CARBON FILTERING MEDIUM |
MEDA | MEDIA FOR WHICH DESIGNED | WATER |
ADNQ | DIFFERENTIAL PRESSURE | 100.0 POUNDS PER SQUARE INCH |
ABPM | BODY DIAMETER | 4.250 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/OUT CONTAINER |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.