Aerospace Performance Parts is pleased to offer immediate purchasing options for Prologic Inc part number A00145, which you have taken interest in. This Powersupply item is listed alongside the NSN 6130-01-620-6131 for ease of identification, with various additional information provided on this page for your reference. Should you wish to obtain solutions on this particular listing, we invite you to complete the Request for Quote (RFQ) form on this page at your earliest convenience. Responses are always offered shortly after we receive and review each request, with solutions we give being fully based on the details we are provided.
Note : We Will Not Share Your Information To Any Third Parties.
If you happen to require expedited shipping for part number A00145 or any other FSC 6130 Converters Electrical Non Rotating components we carry from Prologic Inc under CAGE Code 3TRX0, be sure to let us know as soon as possible. We would be happy to discuss the options that we can potentially provide, our track record of on-time delivery being a testament to our dedication to customer satisfaction. You can either include such details within your request, or get in touch with staff directly. Otherwise, request a quote on NSN 6130-01-620-6131 part number A00145 today, knowing we will support all your operational needs with care.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-620-6131 Item PartTypeName: POWER SUPPLY | 6130 | 016206131 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DCS300 4E M130 EHT OPT | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 19.62 INCHES NOMINAL |
AMQY | Installation Design | RACK |
CWKM | Warm Up Time In Minutes | 30 |
CBBL | Features Provided | DIGITAL AMMETER AND DIGITAL VOLTMETER |
AGAV | End Item Identification | LINK 16 ALASK |
APTQ | Input Frequency Rating | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CWWY | Power Supply Efficiency Line | 85 |
CXCY | Part Name Assigned By Controlling Agency | POWER SUPPLY |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
AKWC | Electrical Power Source Relationship | OPERATING |
BGHY | Output Control Type | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
BGHX | Output Control Quantity | 2 SINGLE POWER OUTPUT |
ABKW | Overall Height | 1.72 INCHES NOMINAL |
CWHM | Input Current Rating | 9.0 AC AMPERES NOMINAL AND 18.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
CWGH | Output Current Rating | 0.0 DC AMPERES MINIMUM AND 4.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
ABMK | Overall Width | 19.00 INCHES NOMINAL |
APPA | Output Voltage Rating | 0.0 DC VOLTS MINIMUM AND 300.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
AYNH | Operating Ambient Temp Range | +0.0 TO 50.0 DEG CELSIUS |
MRC | Decoded Requirement | Clear Text Reply |
CWGZ | Ripple Voltage At Full Load | 25.0 MILLIVOLTS RMS SINGLE POWER OUTPUT |
CWHC | Output Control Location | FRONT PANEL SINGLE POWER OUTPUT |
APNX | Input Voltage Rating | 225.0 AC VOLTS NOMINAL AND 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
BGQR | Output Wattage Rating | 1.2 KILOWATTS MAXIMUM SINGLE POWER OUTPUT |